Electrical cable sizing in Australia is governed by the AS/NZS 3000 wiring rules and depends on several factors together — the current the circuit needs to carry, the length of the cable run (longer runs experience more voltage drop and may need a thicker cable even for the same current), ambient temperature, installation method, and how the cable is grouped with others.
This page is a general educational guide only — actual cable selection and all electrical installation work in Australia must be carried out by a licensed electrician, who will apply the full AS/NZS 3000 requirements specific to your installation, not just the simplified voltage drop estimate below.
Why voltage drop matters over longer cable runs
Every cable has some electrical resistance, which causes a small voltage loss over its length — negligible over a short run, but potentially significant over a long one (like a cable running to a shed, granny flat, or the far end of a large property). AS/NZS 3000 sets maximum allowable voltage drop limits (commonly around 5% of the supply voltage for general circuits), and exceeding this can cause equipment to underperform or overheat. A rough approximate voltage drop can be estimated as Voltage drop ≈ (2 × length × current × resistance per metre) ÷ 1000, where resistance per metre depends on the specific cable's cross-sectional area and material — this is a simplification, and a licensed electrician will use exact AS/NZS 3000 tables and calculation methods for a compliant design.
This is genuinely not a DIY calculation
Beyond voltage drop, correct cable sizing also depends on current-carrying capacity derating for ambient temperature, cable grouping, installation method (in conduit, buried, in open air), and the specific protection device (circuit breaker/fuse) used — getting any of these wrong can create a genuine fire and safety risk. Electrical work in every Australian state and territory legally requires a licensed electrician for anything beyond very limited, prescribed DIY exceptions (which do not include general wiring or cable sizing decisions).
Frequently asked questions
No — general electrical wiring work legally requires a licensed electrician in every Australian state and territory. There are very limited prescribed exceptions for minor DIY electrical work, which do not extend to general circuit wiring or cable sizing.
Longer cable runs experience greater voltage drop for the same current, because resistance increases with length — which can require a larger cross-sectional area cable than a short run carrying the identical load current, purely to keep voltage drop within AS/NZS 3000 limits.
AS/NZS 3000 (the Australian/New Zealand Wiring Rules) sets out the requirements for electrical installations, including cable sizing, protection devices and safety requirements — always engage a licensed electrician who works to this standard.