๐Ÿ‡ฆ๐Ÿ‡บ Free Australian calculators โ€” rates updated for FY2026โ€“27
Home Improvement & Construction

Ramp Gradient Calculator (AS 1428.1)

Work out the minimum length needed for a ramp at a given rise, and check the gradient against the AS 1428.1 accessible ramp standard.

๐Ÿ•’ Updated September 2026๐Ÿ‡ฆ๐Ÿ‡บ Australia-specific๐Ÿ’ฏ Free, no signup

๐Ÿงฎ Calculate your ramp length

Getting a ramp gradient right matters for more than comfort โ€” it's the difference between a ramp that's genuinely wheelchair-accessible and one that technically exists but nobody using a wheelchair, walking frame or pram can safely use unassisted. Australian Standard AS 1428.1 sets out the maximum gradients, landing requirements and handrail rules for accessible ramps.

This calculator works out the minimum ramp length for a given rise and gradient ratio, and flags whether that ratio meets the AS 1428.1 accessible standard.

The key AS 1428.1 numbers

For a continuous accessible ramp, AS 1428.1 sets a maximum gradient of 1:14 (about 7.1%), with a maximum individual run of 9 metres between landings, and landings required at the top, bottom, and at any change of direction. Handrails are required on both sides for most accessible ramps above a certain rise. Steeper ratios (1:10, 1:8) are sometimes used for short domestic ramps under the National Construction Code where full accessibility isn't the goal, but they don't meet the accessible ramp standard.

Why a gentler ratio isn't always better

A 1:20 ramp is easier to use but needs roughly 40% more length than a 1:14 ramp for the same rise โ€” which isn't always physically possible on a tight suburban block. Where space is limited, a compliant 1:14 ramp with a mid-landing (splitting the rise into two shorter runs) is often the practical solution rather than trying to force a single very long, very gentle run.

Frequently asked questions

What is the maximum gradient for a wheelchair ramp in Australia?+

1:14 under AS 1428.1 for a continuous accessible ramp, meaning 1mm of rise for every 14mm of ramp length (about 7.1% grade), with a maximum 9-metre run between landings.

Can I build a steeper ramp than 1:14 at home?+

For a genuinely wheelchair-accessible ramp, no โ€” 1:14 is the maximum under AS 1428.1. Some short domestic ramps not intended to meet the accessible standard use steeper ratios like 1:8 or 1:10, but check your local council and building surveyor's requirements before building, especially if the ramp needs to meet NCC accessibility provisions for a specific use.

Do I need a landing partway up a long ramp?+

Yes โ€” AS 1428.1 requires a landing after a maximum 9-metre run at 1:14, and at the top, bottom, and any change of direction, to give wheelchair users a place to rest and manoeuvre.

How long does a ramp need to be for a 600mm step?+

At 1:14, roughly 8.4 metres (600mm ร— 14). At a gentler 1:20, roughly 12 metres. Enter your exact rise above for a precise figure.

General information only. This calculator provides estimates for planning purposes and does not constitute financial, tax, legal or medical advice. Figures are based on publicly available Australian rates and rules current as of September 2026; always confirm specifics with the ATO, a licensed adviser, or the relevant government body before making a decision.